ACE Home Inspections, LLC

P.O. Box 1993
Alabaster, AL 35007
(205)401-3030

Customer
Report Sample

Home
123 Sample Lane
Birmingham, AL 00000

Real Estate Agent
NONE


Inspection Date 
Thursday, March 29, 2007
Weather:
Clear and Sunny
Report ID:
05950 FINAL REPORT
Temperature:
80 to 85 degrees
Inspected By 
Jeff Aiken

SUMMARY


ACE Home Inspections, LLC

P.O. Box 1993
Alabaster, AL 35007
(205)401-3030

Customer
Report Sample

Home
123 Sample Lane
Birmingham, AL 00000

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitabilty of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation.

This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home.

This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

PORCHES, DECKS, PATIOS, STEPS, STAIRS, RAILINGS, BANISTERS
2.0 PORCHES, DECKS, PATIOS, STEPS, STAIRS, RAILINGS, BANISTERS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-The stairway to the upper rear right office area is wood and appears adequate, however the short four foot section wall at the top is missing a hand-rail. (safety)

EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
3.7 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MISCELLANEOUS INFORMATION
The left side front entry door was not opened because there is a sign stating use the right door only. recommend owner or tenant disclosure on whether or not door is functional.
3.8 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MISCELLANEOUS INFORMATION
The paint finish on the right and rear walls is aged where heavily painting is recommended.
3.9 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
GENERAL ROOF INFORMATION:

Most flat and low pitched roofs roofs have a parapet. It is a low wall along the perimeter that modifies the wind flow over the roof so that the pressure on it is more uniformly distributed. Parapets are essentially the exterior walls that extend a few feet above the roof surface. These short walls also provide a measure of safety in that no objects are so easily blown into the street below. A gravel stop, tar paper, or fiberglass asphalt roll roofing around the perimeter along the parapet provides a finished edge for the built-up roofing.

1,2,3,4,5,6,7,8,9,10-All of this buildings parapets are about 12 inches wide and are made of brick and mortar. The inner or middle parapets that are not along the exterior walls are topped with the original ceramic tile or brick-like caps. These caps are in place to protect or seal the tops and prevent deterioration of the brick and mortar. The original caps on the parapets along the front and right side exterior walls have been removed and replaced with tin caps. This most likely was done for safety reasons to prevent the possibility of a broken cap piece from falling to the ground.

There are several small single flue brick chimneys embedded in the parapets or walls between the buildings that were most likely used years ago for some type of coal or gas heating stoves.

*****The parapet walls appear adequate, however about a half dozen small sections of inner ceramic caps are missing or deteriorated. These sections have been covered with roof roofing or tin. Some of these parapets areas and unused chimney flues are covered with loose bricks or broken sections of parapet. Loose objects on top of a roof can sometimes become hurling objects during a severe storm. It is recommended that all loose items be removed and all parapet caps be secured with roof tar or by other means and all chimney tops be properly sealed with permanent metal caps. (safety)
3.10 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-One of the large front window panes is loose where it has play within the framing when pressed upon. See picture for location.
3.11 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The lower section of the fixed window pane between the two front entry doors and one lower corner of another fixed pane to the left of the front entry are cracked and broken where replacement of each by a licensed glass contractor is recommended.
3.12 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The front wall area is comprised of vinyl and stone and mortar siding. There are noticeable gaps between some of the vinyl siding and the caulking is aged with gaps and cracks around the perimeter of the some windows where new caulking is recommended.
3.13 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The paint covering on the rear wood entry door is aged and there are some small areas of deteriorated wood along the lower sections. Repairs are recommended which may include but are not limited to replacement of deteriorated areas and heavily painting entire door.
3.14 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4-The rear gutters are dirty and some sections are loose. Some downspouts are dented or crushed and have the bottom 45 degree section missing. Recommend a licensed gutter contractor to make needed repairs.
3.15 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8-The rear and right side walls are about 12 inches thick and comprised of brick and mortar with an outer 3/4 to 1-inch concrete covering. The majority of the concrete covering on the right side appears adequate, however there are numerous small missing areas along the rear wall and rear entry door side framing. There are three small circular holes along the rear that protrude into the rear right lower bathroom area for some reason and are no longer being used. The rear wall is comprised of numerous spider web type hairline cracking. The walls appear relatively level and free of major cracking. The concrete covering on the right wall has two full length vertical hairline cracks. These cracks have little to no differential where one side is not further out than the other, indicating most likely they are from normal settlement, and most likely should not pose a problem unless they continue to worsens with time. The concrete covering along the rear section of the right wall was removed and recovered about 3 years ago, according to tenant, and appears adequate.

*****Further investigation and repairs by a licensed siding contractor are recommended which may include but are not limited to patching all missing areas and possibly removal and recovering of the heavily spider-cracked concrete covering areas along the rear wall.
3.16 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15-Built-up roof systems are composed of various materials, such as bitumen, roof tar, felts, and surfacing. Together they create a strong watertight membrane. This particular building is comprised of 4 separate or original buildings. The interior brick walls have been removed and replaced with various columns to make one large open showroom. The roof design is original and is comprised of 4 separate slightly-sloped low pitched roof bays. All water drains down from the front into rear gutters. The roof covering is made of 36 inch wide fiberglass asphalt roll roofing held in place overtop a roof tar or bitumen-like substance.

*****The roof covering is aged and is estimated to be at least 14 or 15 years old based on the heat and air units which are dated 1993. The roof covering appears aged and nearing the end of its normal life span. Each bay has some isolated bubbled or raised, discolored, and low-granule count areas of roof covering where further investigation and any needed repairs by a licensed roof contractor are recommended, before closing.

KITCHEN, BATHROOMS, INTERIOR ROOMS
5.7 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-There are some miscellaneous old wires protruding from the rightmost showroom and rear exterior walls. The interior ones were tested and found not have voltage, however removal of all unused and loose wiring is recommended.
5.8 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2-Some of the fluorescent lighting in the bays and rear office areas do not turn on where repairs are recommended which may include bulb, ballast, or fixture replacement.
5.9 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3-The rear hallway right bathroom is functional, however the water to the left bathroom commode has been turned off. The sink is functional, however the faucet valves are aged and must be turned off very hard to prevent leakage. The bathroom has been filled with old plastic bags and sheeting where the commode area was not readily accessible. The bathroom had a very STRONG odor of sewage at the time of inspection. Further investigation and repairs are recommended by a licensed plumbing contractor which should include elimination of sewage odor.
5.10 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-The exhaust fan is functional in the rear hallway left bathroom, however the one in the right bathroom is not. The ceiling in the right bathroom is cracked, and there is a small wire and switch beside the ceiling vent where purpose is not known.
5.11 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3,4,5,6-The vinyl, linoleum, and carpet floor coverings are aged with missing, curled, and dirty areas throughout the bay areas.
5.12 KITCHEN, BATHROOMS, INTERIOR ROOMS
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8,9,10,11,12,13-There are numerous small isolated areas of brown discolored and deteriorated ceilings and walls throughout all the bays that were reported to be no longer leaking. Recommend a licensed general contractor to make ceiling and wall covering repairs. (cosmetic)
5.13 KITCHEN, BATHROOMS, INTERIOR ROOMS
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The rear hallway right bathroom door is damaged and the striker mechanism for the door knob is missing.
5.14 KITCHEN, BATHROOMS, INTERIOR ROOMS
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The paint finish on the interior wood sills surrounding the front windows is aged with cracked, peeled, and missing areas and some small isolated areas are deteriorated. Repairs are recommended which may include but are not limited to replacement of deterioration and heavily painting of all areas.
5.15 KITCHEN, BATHROOMS, INTERIOR ROOMS
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The rear upper right bathroom light fixture is hanging loose, and a couple lamps have been attached to the wall in the rear lower hallway. Repairs are recommended by a licensed electrical contractor which may include but are not limited to replacement of all makeshift lighting with permanent type lighting that turns on from a wall switch.
5.16 KITCHEN, BATHROOMS, INTERIOR ROOMS
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The rear upper right bathroom commode is loose where it mounts to the floor and the water tank is broken where repairs are recommended by a licensed plumbing contractor.
5.17 KITCHEN, BATHROOMS, INTERIOR ROOMS
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2-The drain piping under the rear right lower bathroom pedestal sink and the rear center hallway left wall sink was not leaking, however has some corroded areas where replacement is recommended.

3-The drain piping under the rear upper right bathroom sink is adequate, however the piping travels through a crude hole in the wall. (cosmetic)

4-The drain piping under the rear center hallway right bathroom sink is aged and has a sizeable leak that was observed after the basin was filled and allowed to drain.
5.18 KITCHEN, BATHROOMS, INTERIOR ROOMS
MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
The ceilings, walls, around the front windows, and the ceilings where two buildings adjoin have numerous areas of brown moisture discolored and deteriorated areas from previous leakage. The present tenant pointed out 5 separate areas of leakage which are listed below. The numbers correspond to the appropriate pictures.

1,2,3,4,5,6-The carpet gets wet in the right corner of the rear lower right office whenever it rains. Three years ago the upper office ceiling and lower office corner floor area were leaking. Repairs were made at that time which involved resurfacing the rear end of the right exterior wall and some roof covering repairs along with repairs to a badly deteriorated upper office plasterboard ceiling. The upper office leak was repaired, however the lower office floor leak is still present, but not as bad as it was. The walls sound like falling plaster or sand when the wood paneling is pressed against. The spider-web cracking of the 1-inch concrete covering may be the problem where water seeps in when it rains, however the roof may still be leaking water down the wall?

7,8,9,10-One area along the front wall where bay three meets the leftmost bay. Water drains down the ceiling and wall onto the window ledge area whenever it rains. This most likely is a front roof covering or parapet problem?

11-Water drips down beside from the ceiling in the third bay from the right rear workshop area ceiling fan.

12,13-Water drips down in a couple places in the left most bay rear open metal truss ceiling room, one towards the middle and another along the rear wall. These two leaks were reported to only leak during a hard and prolonged rain.

*****Repairs all of leakage areas are recommended by a licensed roof contractor, before closing.

PLUMBING (Main, Exterior, Water Heater, Washer, Dryer)
6.4 PLUMBING SYSTEM
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2-One natural gas supply has been removed along the right side. The supply for the 4 natural gas furnaces located on top the roof was not located where owner disclosure of meter location is recommended.

ELECTRICAL (Service, Interior Distribution Panels, Exterior)
7.7 ELECTRICAL SYSTEM
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7-Readily accessible outlets were tested with a SureTest electrical tester and found to be a mix of grounded and ungrounded. Some of the original 2-prong outlets have been replaced with modern 3-prong outlets, however it is important to note that just because it has 3 prongs, does NOT mean that it is grounded. This should be expected for a building of this age where owner is NOT required to upgrade. The outlets have the proper voltage and are functional, however it is always advisable to have grounded outlets. Computers are very sensitive devices, and commonly experience data corruption in non-grounded environments. Ungrounded outlets pose a safety hazard and are in violation of the building and national wiring codes. It is recommended, but not required, based on the age of the house, that a licensed electrical contractor upgrade all ungrounded outlets, which most likely will involve replacement of some of the wiring.
7.8 ELECTRICAL SYSTEM
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2-There are two outlet covers in the rear lower right office that are missing a cover. There may be others throughout the building that were not located due to tenant stored items. (safety)
7.9 ELECTRICAL SYSTEM
MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-There are wires in a small junction box located on the ceiling in the rear lower right office ceiling that is missing a cover. (safety)
7.10 ELECTRICAL SYSTEM
MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8,9,10,11,12,13,14-The building has about a dozen fused and breaker type electrical panels. All the these panels are basically located along the rear wall within each bay. There are some electrical issues in need of repair which are listed below.

A-The majority of all panel covers were found to be missing or unattached. Some covers were found nearby. This exposes live voltage creating a safety issue where installation a cover over ALL electrical panels is recommended, before closing.

B-The fuse panels have some 12 and 14-gauge wiring connected to 30-amp glass plug fuses. The 12 gauge wiring should have 20 amp fuses, 14 gauge wiring should have 15 amp fuses, and only the 10 gauge wiring should have 30 amp fuses. Further investigation and any necessary repairs by a licensed electrical contractor are recommended for the overfused wiring which could be considered a fire hazard, before closing. Repairs may include but are not limited to upgrading fuse panel with a breaker panel.

C-Some of the sub-panels were found to have the ground and neutral wires on the same bar. All sub-panels should have the neutral (white) wires separated from the ground (bare) wires. Mixing these on the same bar allows the possible potential for voltage to be present on the grounding system. Opinions by licensed electrical contractors on this panel issue varies between safe and unsafe. I recommend you consult a licensed electrical contractor for an opinion and correct if necessary.

D-The rear wall of the second from the right bay contains the majority of the electrical panels. There are also numerous disconnect panels, and runs of conduit and wiring. Some areas are readily accessible within the small break room, however some panels and wiring is located directly above the former and now enclosed rear entry area. This area is accessible through a small opening above the hallway refrigerator. There was 120 and 240 voltage measured on the panels along this area, indicating this equipment is still be used in some capacity. There are also some old conduit, wiring, armored type cabling, and disconnects which appear to no longer be in-use which still have power connected. This entire rear wall area appears very congested and based on all the missing covers, over-fusing, and aged cabling, it is recommended that a licensed electrical contractor further investigate and repair, which may include but is not limited to removal of all unused components and an overall 'clean-up' of what could be considered a fire-hazard area, before closing.

Refer to report section 7.6 for additional information.

HEATING SYSTEM
8.4 HEATING SYSTEM
MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-The heating and air unit in the second from the right bay was not functional at the time of inspection. The unit made an attempt to turn on when first operated from the thermostat then quickly shut-off and would not turn on again after numerous attempts. A new breaker box was installed most likely six years ago for the four units. All breakers were on where a cartridge fuse in the service disconnect on top of the roof at the unit may be blown? Repairs and system service by a licensed heating and air contractor are recommended, before closing.

ACE Home Inspections, LLC

Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

ACE Home Inspections, LLC

Prepared Using HomeGauge http://www.homegauge.com/ SHGI (c) 2000-2003 : Licensed To Jeffrey James Aiken

 

WALKWAYS, DRIVEWAYS, LANDSCAPING, RETAINING WALLS

Styles & Materials
LANDSCAPING:
LEVEL PROPERTY
NO TREES OR SHRUBS
RETAINING WALLS:
NONE
WALKWAYS:
FRONT CITY SIDEWALK
RIGHT SIDE CITY SIDEWALK
DRIVEWAYS:
FRONT PAVED STREET PARKING
RIGHT SIDE PAVED STREET
REAR PAVED ALLEY STREET



Inspection Items
1.0 WALKWAYS, DRIVEWAYS, LANDSCAPING, RETAINING WALLS
Picture 1
Picture 2
Picture 3
Comments: FOR YOUR INFORMATION
1,2,3-The property is level and is surrounded by streets and sidewalks on the front, right and rear. The left side adjoins to a lock and mower repair shop building.
1.1 WALKWAYS, DRIVEWAYS, PATIOS, LANDSCAPING, RETAINING WALLS (Visible condition. Checking for proper water runoff away from the house, the landscape for presence of holes, sunken areas, bald spots, eroding areas, and tripping hazards, trees and vegetation clearances, and drainage weep holes or drains at the base of retaining walls.)
Comments: INSPECTED

PORCHES, DECKS, PATIOS, STEPS, STAIRS, RAILINGS, BANISTERS

Styles & Materials
STEPS AND STAIRWAYS:
INTERIOR WOOD STAIRWAY
LOCATED REAR RIGHT SIDE
RAILINGS AND BANISTERS:
WOOD BANISTER RAILING



Inspection Items
2.0 PORCHES, DECKS, PATIOS, STEPS, STAIRS, RAILINGS, BANISTERS
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-The stairway to the upper rear right office area is wood and appears adequate, however the short four foot section wall at the top is missing a hand-rail. (safety)
2.1 PORCH (Visible condition of roof, eaves, gutters, attic, ventilation, columns, foundation, floor, coverings, storage closets.)
Comments: NOT PRESENT
2.2 DECK (Visible condition. Checking roof, roof support structures, attic, ceilings, screens, gates, doors, if deck support columns are resting on concrete footers, and if deck is secured properly with lag bolts or a ledgerboard with metal joist brackets.)
Comments: NOT PRESENT
2.3 STOOPS, STEPS, STAIRS, BANISTERS, AND RAILINGS (Visible condition. Checking for potential tripping hazards from variations in step riser heights, narrow tread steps, unlevel steps or steep stairs. Checking for adequate headroom.)
Comments: INSPECTED

EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY

Styles & Materials
DOOR INFO:
TWO GLASS FRONT ENTRY
WOOD SLIDING REAR ENTRY
WINDOWS:
FIXED GLASS PANES
ALUMINUM FRAMING
SIDING MATERIAL:
FRONT STONE AND MORTAR
REST IS BRICK AND MORTAR
COVERED WITH 1-INCH CONCRETE
GUTTER MATERIAL:
REAR ALUMINUM GUTTERS
FOUNDATION MATERIAL:
POURED CONCRETE
VIEWED ROOF FROM:
WALK ENTIRE ROOF/USE LADDER
ROOF TYPE:
FLAT
SLIGHTLY SLOPED DOWN TO REAR
ROOF COVERING:
36 INCH WIDE ROLL
FIBERGLASS ASPHALT MATERIAL
OVER ROOF TAR BASE
LAYERS:
ONE
ESTIMATED ROOF AGE:
15 TO 20 YEARS
ROOF VENTILATION:
REAR RECTANGULAR WALL VENTS
CHIMNEY(S):
SOME WITHIN PARAPETS
SKY LIGHT (S):
NONE
ROOF PENETRATIONS:
2 ROOF CONE VENTS PER BAY
1 REAR ASBESTOS FLUE PER BAY
1 HEAT/COOL UNIT PER BAY



Inspection Items
3.0 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: FOR YOUR INFORMATION
1-One roof bay has a functional 120 volt GFCI type electrical outlet. This is good!
3.1 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
There are some asbestos flue pipes protruding through the rear end of the three rightmost bays on top of the roof. These appear to no longer be in use and most likely can be removed the next time the roof is recovered. *****This 7 inch ceramic/asbestos type piping is known as Transite. This can be used for both a furnace and water heater, however is no longer considered a type "B" vent.
3.2 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
1-A few small square sheets of wood are attached to the exterior walls. These may have been used at one time for windows or a/c units. Unknown?
3.3 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Comments: MISCELLANEOUS INFORMATION
1,2,3-Attic ventilation appears adequate and is listed below.

-Each bay has two cone-like vents protruding through the roof covering and the two middle bays also have rectangular vents along the rear. This is good!
3.4 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
1-There 2nd from the right building used to have a rear customer entry door area. The outer area has been completely and permanently sealed with steel plates and bars welded in place. The tri-angular entry door area and glass entry doors still exist and have been covered or sealed with plywood along the rear hallway area.
3.5 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
1-There are some miscellaneous and now unused sections of wiring, conduit, and small disconnect panels along the rear wall that can be removed, if desired.
3.6 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
The front stone and mortar siding is relatively level and free of major cracks and deterioration. There are some small minor cracks, with no side-to-side differential, where one side is not further out than the other, indicating most likely they are from normal settlement, and should not pose a problem unless they loosen and crumble with time.
3.7 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
The left side front entry door was not opened because there is a sign stating use the right door only. recommend owner or tenant disclosure on whether or not door is functional.
3.8 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MISCELLANEOUS INFORMATION
The paint finish on the right and rear walls is aged where heavily painting is recommended.
3.9 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Picture 9
Picture 10
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
GENERAL ROOF INFORMATION:

Most flat and low pitched roofs roofs have a parapet. It is a low wall along the perimeter that modifies the wind flow over the roof so that the pressure on it is more uniformly distributed. Parapets are essentially the exterior walls that extend a few feet above the roof surface. These short walls also provide a measure of safety in that no objects are so easily blown into the street below. A gravel stop, tar paper, or fiberglass asphalt roll roofing around the perimeter along the parapet provides a finished edge for the built-up roofing.

1,2,3,4,5,6,7,8,9,10-All of this buildings parapets are about 12 inches wide and are made of brick and mortar. The inner or middle parapets that are not along the exterior walls are topped with the original ceramic tile or brick-like caps. These caps are in place to protect or seal the tops and prevent deterioration of the brick and mortar. The original caps on the parapets along the front and right side exterior walls have been removed and replaced with tin caps. This most likely was done for safety reasons to prevent the possibility of a broken cap piece from falling to the ground.

There are several small single flue brick chimneys embedded in the parapets or walls between the buildings that were most likely used years ago for some type of coal or gas heating stoves.

*****The parapet walls appear adequate, however about a half dozen small sections of inner ceramic caps are missing or deteriorated. These sections have been covered with roof roofing or tin. Some of these parapets areas and unused chimney flues are covered with loose bricks or broken sections of parapet. Loose objects on top of a roof can sometimes become hurling objects during a severe storm. It is recommended that all loose items be removed and all parapet caps be secured with roof tar or by other means and all chimney tops be properly sealed with permanent metal caps. (safety)
3.10 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-One of the large front window panes is loose where it has play within the framing when pressed upon. See picture for location.
3.11 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The lower section of the fixed window pane between the two front entry doors and one lower corner of another fixed pane to the left of the front entry are cracked and broken where replacement of each by a licensed glass contractor is recommended.
3.12 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The front wall area is comprised of vinyl and stone and mortar siding. There are noticeable gaps between some of the vinyl siding and the caulking is aged with gaps and cracks around the perimeter of the some windows where new caulking is recommended.
3.13 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The paint covering on the rear wood entry door is aged and there are some small areas of deteriorated wood along the lower sections. Repairs are recommended which may include but are not limited to replacement of deteriorated areas and heavily painting entire door.
3.14 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4-The rear gutters are dirty and some sections are loose. Some downspouts are dented or crushed and have the bottom 45 degree section missing. Recommend a licensed gutter contractor to make needed repairs.
3.15 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Comments: MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8-The rear and right side walls are about 12 inches thick and comprised of brick and mortar with an outer 3/4 to 1-inch concrete covering. The majority of the concrete covering on the right side appears adequate, however there are numerous small missing areas along the rear wall and rear entry door side framing. There are three small circular holes along the rear that protrude into the rear right lower bathroom area for some reason and are no longer being used. The rear wall is comprised of numerous spider web type hairline cracking. The walls appear relatively level and free of major cracking. The concrete covering on the right wall has two full length vertical hairline cracks. These cracks have little to no differential where one side is not further out than the other, indicating most likely they are from normal settlement, and most likely should not pose a problem unless they continue to worsens with time. The concrete covering along the rear section of the right wall was removed and recovered about 3 years ago, according to tenant, and appears adequate.

*****Further investigation and repairs by a licensed siding contractor are recommended which may include but are not limited to patching all missing areas and possibly removal and recovering of the heavily spider-cracked concrete covering areas along the rear wall.
3.16 EXTERIOR DOORS, WINDOWS, SIDING, FOUNDATION, GUTTERS, ROOF, CHIMNEY
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Picture 9
Picture 10
Picture 11
Picture 12
Picture 13
Picture 14
Picture 15
Comments: MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15-Built-up roof systems are composed of various materials, such as bitumen, roof tar, felts, and surfacing. Together they create a strong watertight membrane. This particular building is comprised of 4 separate or original buildings. The interior brick walls have been removed and replaced with various columns to make one large open showroom. The roof design is original and is comprised of 4 separate slightly-sloped low pitched roof bays. All water drains down from the front into rear gutters. The roof covering is made of 36 inch wide fiberglass asphalt roll roofing held in place overtop a roof tar or bitumen-like substance.

*****The roof covering is aged and is estimated to be at least 14 or 15 years old based on the heat and air units which are dated 1993. The roof covering appears aged and nearing the end of its normal life span. Each bay has some isolated bubbled or raised, discolored, and low-granule count areas of roof covering where further investigation and any needed repairs by a licensed roof contractor are recommended, before closing.
3.17 WINDOWS, SHUTTERS AND AWNINGS (Visible condition and checking for the presence and functionality of window flashing and operation of windows and window locks.)
Comments: INSPECTED
3.18 ENTRY DOORS, STORM DOORS, SECURITY DOORS, AND DOORBELL (Visible condition and operation, checking hardware, locks, coverings, frame, trim, weatherstripping, presence of deadbolts on all exterior doors, proper locking, opening, and closing of sliding glass doors, and the presence of a security dead-pin in all sliding glass doors.)
Comments: INSPECTED
3.19 FOUNDATION WALLS AND MORTAR JOINTS (Visible condition, checking for cracked, crumbled, loose, missing, eroded areas, or large gaps)
Comments: INSPECTED
3.20 EXTERIOR WALL COVERINGS, FLASHING,TRIM, AND CAULKING (Visible condition. A wall flashing is defined as a material used around angles or junctions on exterior walls to prevent water leakage.)
Comments: INSPECTED
3.21 HOUSE FRAMING (Visible condition, checking for any cracks developing outside of the house, cracks between a chimney and the exterior wall or any cracks running outward at an angle from the upper corners of windows and door frames.)
Comments: INSPECTED
3.22 OUTSIDE ACCESS TO HOUSE IS RODENT PROOF
Comments: INSPECTED
3.23 ROOF COVERING (Visible condition. Checking roof penetrations such as, roof vents, ridge vents, wind turbines, soffit vents, gable vents, chimneys, furnace flues, water heater flues, plumbing vents, skylights and any other penetrations. Checking flashings which are used to seal around roof penetrations and intersections. Checking rain caps on chimneys and flues.)
Comments: INSPECTED
3.24 SOFFIT, FASCIA, EAVES, GUTTERS, DOWNSPOUTS (Visible condition. Checking if gutters are provided where necessary, including porches, flat roofs, and dormers. Checking whether splasblocks are in place if underground piping is not used for rain gutter drainage.)
Comments: INSPECTED

ATTIC, ROOF INTERIOR

Styles & Materials
ROOF STRUCTURE (2nd and 3rd bays):
2 x 6 WOOD RAFTERS
1 x 6 ROOF DECKING BOARDS
1 x 8 ROOF DECKING BOARDS
CEILING STRUCTURE (2nd and 3rd bays):
2 x 12 WOOD CEILING JOISTS
RAFTER SPACING (2nd and 3rd bays):
16 INCHES
JOIST SPACING (2nd and 3rd bays):
16 INCHES
INSULATION TYPE:
NONE
ATTIC INFO:
RIGHT BAY INFO UNKNOWN
FRONT OF LEFT BAY UNKNOWN
LEFT BAY REAR STEEL TRUSSES
LEFT BAY REAR OPEN CEILING



Inspection Items
4.0 ATTIC, ROOF INTERIOR
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Comments: FOR YOUR INFORMATION
1,2,3,4,5,6,7,8-The one large open showroom, as stated earlier, used to be 4 separate buildings with a 12 inch thick brick wall. Since each wall extends several feet above the roof line, there are 4 completely separate and isolated attic areas. Only the lower sections of wall between each building have been removed to form the open showroom area. The sections within the attic are still intact.

The second from the right bay was the only attic area that was viewable for inspection. The ceilings within the other three bays are completely sealed where no openings were observed.

The second from the right bay attic has a couple rectangular openings along the rear wall above the now sealed off former entry area. The attic starts out higher in the front and narrows at the rear because of the sloped roof. The attics are not readily accessible, because the ceilings consist of wood framing boards and thin plasterboard panels which do not have the strength for support, however enough was able to be viewed in order to gain a general understanding of overall attic construction. Please note that the two center bays and the front half of the left bay have similar or like construction and have the same ceiling height, however the right bay ceiling is about 1.5 foot higher or closer to the roof, and the rear half of the left bay is open with metal truss type construction.

Refer to the Styles and Materials section at the beginning of section 4.0 for overall attic construction information.
4.1 ATTIC, ROOF INTERIOR (Visible condition. Checking attic insulation, exposed wiring, lights and water pipes. Checking to see that all attic areas are accessible, all exposed sections of chimney in attic are free of soot and creosote leakage, that soffit vents are not covered with insulation, and attic ventilation vent screening which keeps animals out)
Comments: INSPECTED
4.2 GAS FLUE AND CHIMNEY FIRESTOPPING (Visible condition. Firestopping refers to size of the hole made in the ceiling and roof so as to maintain the proper clearance from a hot metal flue pipe or chimney brick.)
Comments: INSPECTED
4.3 DO ALL FLUES AND VENTS PRESENT IN ATTIC TERMINATE TO THE EXTERIOR (Water heater flue, furnace flue, metal chimney flue, plumbing vents, bathroom fan vents, range hood vent, dryer vent, etc...)
Comments: INSPECTED
4.4 RAFTERS, DECKING, JOISTS OR TRUSSES (Visible condition. Check for rafters pulling away from ridge board, rot, cracks, splits, cut, altered or missing supports.)
Comments: INSPECTED
4.5 IS ATTIC FREE OF VISIBLE ROOF LEAKS OR DETERIORATION (Flashing refers to materials, usually metal, that join parts of the house to the roof. Common places where roof leaks occur are flashings around chimneys, metal gas flues, plumbing vents, turbines, dormers, valleys, or any other roof penetrations or intersections.)
Comments: INSPECTED
4.6 IS ATTIC FREE OF VISIBLE CONDENSATION OR MOISTURE DAMAGE DUE TO IMPROPER VENTILATION (Often what appears to be a leak is in fact condensation, and a sign of inadequate ventilation. Proper attic ventilation reduces heat in summer and prevents condensation in winter. It allows air to carry off water vapor before it can condense and cause moisture damage.)
Comments: INSPECTED
4.7 INSTALLED MECHANICAL VENTILATION SYSTEMS (Visible condition and operation of power ventilators and fans)
Comments: INSPECTED

KITCHEN, BATHROOMS, INTERIOR ROOMS

Styles & Materials
INTERIOR CEILING MATERIALS:
PLASTERBOARD SQUARE PANELS
WOOD BOARD PANEL FRAMING
ALL OVER HARDWOOD T&G
INTERIOR WALL MATERIALS:
PLASTER
PLASTERBOARD
CONCRETE
BRICK AND MORTAR
INTERIOR FLOOR MATERIALS:
CONCRETE
BATHROOMS:
4 HALF BATHROOMS
BATHROOM INFO:
1 WALL SINK EACH
1 COMMODE EACH
BATHROOM INFO:
1 REAR WALL LEFT CENTER
1 REAR WALL RIGHT CENTER
OTHER INTERIOR INFO:
3 BAYS ARE 12FT HIGH
RIGHT BAY IS 13.7 FT HIGH
OTHER INTERIOR INFO:
4 SEPARATE BAYS
FORMERLY 4 SEPARATE BUILDINGS
OTHER INTERIOR INFO:
OPEN WALLS BETWEEN BAYS
REAR RIGHT UPPER OFFICES
REAR RIGHT LOWER OFFICES
OTHER INTERIOR INFO:
REAR WALL HALLWAY/RESTROOMS
FORMER REAR WALL ENTRY
REAR HALLWAY SIDE ROOM
OTHER INTERIOR INFO:
REAR OFFICE WALK-IN SAFE
BY SARRGENT & GREENLEAF
FIREPROOF ENCLOSURE
OTHER INTERIOR INFO:
5 FOTOVU SECURITY CAMERAS
REAR WALL WORKBENCH AREA
BUILDING DIMENSIONS:
104FT WIDE X 98FT DEEP



Inspection Items
5.0 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Comments: FOR YOUR INFORMATION
1-The interior side of the right wall has some recessed areas, most likely from previous windows.
5.1 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Comments: FOR YOUR INFORMATION
1,2,3,4-Each bathroom sink basin was filled in order to pressurize the piping to inspect for leakage.
5.2 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
1-The rear lower right office area has a large very old walk-in safe. The safe is solid concrete and has a fireproof door. Tenant stated that the safe no longer locks however the handle does properly latch where the door is properly closed and sealed.
5.3 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
The left bay is open however has been divided into three rooms, the front and middle are showrooms, while the rear is used for storage.
5.4 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
The building does not have a kitchen area or appliances. There is a small break room along the rear hallway that has a microwave and two refrigerators.
5.5 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MISCELLANEOUS INFORMATION
1-The front of the right bay has a lower area that has what appears to be a scuttle hole. This was pushed on and found to be permanently attached where there is no entry to this small area.
5.6 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MISCELLANEOUS INFORMATION
Tenant pointed out that the repairs done to the rear upper right office area ceiling was adequate where there has been no further leakage, however the new plasterboard installed in wavy and not level. It was installed over some uneven ceiling joists, however is still functional. (cosmetic)
5.7 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-There are some miscellaneous old wires protruding from the rightmost showroom and rear exterior walls. The interior ones were tested and found not have voltage, however removal of all unused and loose wiring is recommended.
5.8 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2-Some of the fluorescent lighting in the bays and rear office areas do not turn on where repairs are recommended which may include bulb, ballast, or fixture replacement.
5.9 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3-The rear hallway right bathroom is functional, however the water to the left bathroom commode has been turned off. The sink is functional, however the faucet valves are aged and must be turned off very hard to prevent leakage. The bathroom has been filled with old plastic bags and sheeting where the commode area was not readily accessible. The bathroom had a very STRONG odor of sewage at the time of inspection. Further investigation and repairs are recommended by a licensed plumbing contractor which should include elimination of sewage odor.
5.10 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1-The exhaust fan is functional in the rear hallway left bathroom, however the one in the right bathroom is not. The ceiling in the right bathroom is cracked, and there is a small wire and switch beside the ceiling vent where purpose is not known.
5.11 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3,4,5,6-The vinyl, linoleum, and carpet floor coverings are aged with missing, curled, and dirty areas throughout the bay areas.
5.12 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Picture 9
Picture 10
Picture 11
Picture 12
Picture 13
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2,3,4,5,6,7,8,9,10,11,12,13-There are numerous small isolated areas of brown discolored and deteriorated ceilings and walls throughout all the bays that were reported to be no longer leaking. Recommend a licensed general contractor to make ceiling and wall covering repairs. (cosmetic)
5.13 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The rear hallway right bathroom door is damaged and the striker mechanism for the door knob is missing.
5.14 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The paint finish on the interior wood sills surrounding the front windows is aged with cracked, peeled, and missing areas and some small isolated areas are deteriorated. Repairs are recommended which may include but are not limited to replacement of deterioration and heavily painting of all areas.
5.15 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2,3-The rear upper right bathroom light fixture is hanging loose, and a couple lamps have been attached to the wall in the rear lower hallway. Repairs are recommended by a licensed electrical contractor which may include but are not limited to replacement of all makeshift lighting with permanent type lighting that turns on from a wall switch.
5.16 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1-The rear upper right bathroom commode is loose where it mounts to the floor and the water tank is broken where repairs are recommended by a licensed plumbing contractor.
5.17 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Picture 4
Comments: MINOR REPAIRS, (REFER TO REPORT PICTURES)
1,2-The drain piping under the rear right lower bathroom pedestal sink and the rear center hallway left wall sink was not leaking, however has some corroded areas where replacement is recommended.

3-The drain piping under the rear upper right bathroom sink is adequate, however the piping travels through a crude hole in the wall. (cosmetic)

4-The drain piping under the rear center hallway right bathroom sink is aged and has a sizeable leak that was observed after the basin was filled and allowed to drain.
5.18 KITCHEN, BATHROOMS, INTERIOR ROOMS
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6
Picture 7
Picture 8
Picture 9
Picture 10
Picture 11
Picture 12
Picture 13
Comments: MORE THAN MINOR REPAIRS, (REFER TO REPORT PICTURES)
The ceilings, walls, around the front windows, and the ceilings where two buildings adjoin have numerous areas of brown moisture discolored and deteriorated areas from previous leakage. The present tenant pointed out 5 separate areas of leakage which are listed below. The numbers correspond to the appropriate pictures.

1,2,3,4,5,6-The carpet gets wet in the right corner of the rear lower right office whenever it rains. Three years ago the upper office ceiling and lower office corner floor area were leaking. Repairs were made at that time which involved resurfacing the rear end of the right exterior wall and some roof covering repairs along with repairs to a badly deteriorated upper office plasterboard ceiling. The upper office leak was repaired, however the lower office floor leak is still present, but not as bad as it was. The walls sound like falling plaster or sand when the wood paneling is pressed against. The spider-web cracking of the 1-inch concrete covering may be the problem where water seeps in when it rains, however the roof may still be leaking water down the wall?

7,8,9,10-One area along the front wall where bay three meets the leftmost bay. Water drains down the ceiling and wall onto the window ledge area whenever it rains. This most likely is a front roof covering or parapet problem?

11-Water drips down beside from the ceiling in the third bay from the right rear workshop area ceiling fan.

12,13-Water drips down in a couple places in the left most bay rear open metal truss ceiling room, one towards the middle and another along the rear wall. These two leaks were reported to only leak during a hard and prolonged rain.

*****Repairs all of leakage areas are recommended by a licensed roof contractor, before closing.
5.19 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
ACE Home Inspections, LLC only tests a random sampling of house smoke alarms always recommends that ALL smoke alarms be tested and replaced if found defective before moving in.
5.20 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
ACE Home Inspections, LLC is not a licensed air quality, odor, or environmental expert and makes no conclusions as to any of the homes various odors or air quality other than noting any obvious apparent markings on floor coverings from normal wear and tear or from animals such as dogs, cats, or rodents. ACE Home Inspections, LLC always recommends used carpets be properly cleaned by a licensed carpet contractor and an air quality or environmental expert be contacted if client recognizes or concludes themselves that any apparent odors are present, before closing. ACE Home Inspections, LLC does not dismantle or open any non readily accessible areas such as air vents or ductwork and does not move objects or furniture and is not responsible for hidden or latent defects of any kind such as any cracked tile or torn and soiled carpet under furniture. ACE Home Inspections, LLC offers no warranties or guarantees and lists all conditions at the time of inspection, where the inspection is like a snapshot in time. For example a component proved to be in working order at time of inspection, could be malfunctioning soon after moving in at no fault of ACE Home Inspections, LLC.
5.21 KITCHEN, BATHROOMS, INTERIOR ROOMS
Comments: FOR YOUR INFORMATION
ACE Home Inspections, LLC offers no warranties or guarantees. A home inspection is like a snap shot in time where component conditions are noted at the time of inspection. ACE Home Inspections, LLC is not responsible for component conditions occurring after the time of the inspection.
5.22 KITCHEN (Visible condition of ceiling, walls, cabinets, shelving, countertops, plumbing. Checking that all outlets within six feet of sink have GFCI protection, and there are separate water shut-off valves for faucet, dishwasher, and ice-maker.)
Comments: NOT PRESENT
5.23 ARE FAUCETS FREE OF HAMMERING AND VIBRATING NOISES WHEN TURNED ON/OFF RAPIDLY (This occurs when water flowing in the pipe comes to an abrupt stop, introducing shock and vibrations that can damage pipes or fittings. It is caused by improper sized pipes and can be fixed with an air chamber or antiknock coil which provides an air cushion to absorb shock.)
Comments: INSPECTED
5.24 DOES SINK DRAIN INTO A P-TRAP UNDER THE SINK (A trap is needed to provide a water seal that blocks sewer gases from seeping back into house. Some homes still have S-type traps that do not always vent properly. If a sucking and gurgling noise occurs after almost all the water has drained, the water seal has been lost. All S-traps should be converted to P-traps.)
Comments: INSPECTED
5.25 DOES SINK HAVE AN AIR GAP TO PREVENT BACK SIPHONAGE (Simply speaking, the air gap prevents the dirty sink water from being sucked back into the clean water supply pipes through the end of the faucet if the sink should overflow. There should be a gap of at least 1 inch between the end of the faucet where the water exits and the flood rim of the sink.)
Comments: INSPECTED
5.26 IS THERE A GAS SHUT-OFF VALVE AND DRIP LEG OR IN-LINE CLEANER (A drip leg or dirt pocket is a short capped off pipe added into gas line serving as a collection area for sediment to reduce the chance of clogged valves or burners.)
Comments: INSPECTED
5.27 INTERIOR ROOMS (Visible condition of ceilings and walls.)
Comments: INSPECTED
5.28 INTERIOR ROOMS (Visible condition and operation of windows, doors, floors, lights, switches, outlets)
Comments: INSPECTED
5.29 BATHROOM (Visible condition of ceiling, walls, cabinets, countertops, and caulking.)
Comments: INSPECTED
5.30 BATHROOM (Visible condition and operation of windows, doors, floor, cabinet doors, drawers, exhaust fans, lights, switches, outlets, sinks, tubs, showers, and commodes. Checking presence of cut-off valves for faucets and commodes, proper draining of sinks, tubs, showers and commodes, use of P-traps and not old S-traps, proper air-gap for sinks, tubs, and hand-held shower wands to prevent back siphonage, faucets for improper hammering and vibrating noises when turned on/off rapidly, adequacy of hot and cold water pressure, volume, and temperature, exhaust fans for proper venting to building exterior and outlet GFCI protection.)
Comments: INSPECTED

PLUMBING (Main, Exterior, Water Heater, Washer, Dryer)

Styles & Materials
PLUMBING SUPPLY:
METAL PIPE
DISTRIBUTION:
METAL PIPE
PLUMBING WASTE:
CAST IRON/METAL PIPE
WHITE PVC(polyvinyl chloride) PIPING
WASTE SYSTEM:
UNKNOWN
WATER SOURCE:
PUBLIC
BATHROOM SINK PLUMBING:
WHITE PVC(polyvinyl chloride) PIPING
METAL DRAIN PIPING
GRAY TUBING WATER LINES
WHITE PLASTIC FLEX HOSE
COPPER WATER CONNECTIONS
WATER HEATER BRAND/DATE:
NONE PRESENT



Inspection Items
6.0 PLUMBING SYSTEM
Comments: FOR YOUR INFORMATION
The building has a total of 4 half bathrooms. Each contains only one commode and one sink. There are no tubs or showers.
6.1 PLUMBING SYSTEM
Comments: FOR YOUR INFORMATION
The building does not have a water heater where each sink is pipe with only cold water.
6.2 PLUMBING SYSTEM
Comments: MISCELLANEOUS INFORMATION
1-The rear hallway area has a small canister type water filter. The piping is no longer hooked up and most likely was previously used for a drinking fountain?
6.3 PLUMBING SYSTEM
Comments: MISCELLANEOUS INFORMATION
ACE Home Inspections, LLC does not inspect sewage and septic systems or cleanouts, hidden piping, or test floor or laundry drains. Plumbing inspection consists solely of visible areas, operation of all faucets, the filling of all sink basins, and water heater operation.
6.4 PLUMBING SYSTEM
Picture 1
Picture 2
Comments: MISCELLANEOUS INFORMATION, (REFER TO REPORT PICTURES)
1,2-One natural gas supply has been removed along the right side. The supply for the 4 natural gas furnaces located on top the roof was not located where owner disclosure of meter location is recommended.
6.5 WATER HEATER, PTV - PRESSURE TEMPERATURE VALVE, PTV DRAIN PIPING (Visible condition. Checking presence of a drain pan under unit if installed in attic or room over a living area, and presence of a cold water inlet water cut-off valve.)
Comments: NOT PRESENT
6.6 EXPOSED INTERIOR WATER PIPING (Visible condition, looking for leaks, corrosion, sagging sections, and valves where it enters house and stops at the point where it enters rooms where it then will